Hi! Recirculating Chiller Series

Recirculating chillers for external equipment: LC heating/cooling models (to −80 °C on LC-80) and TLC cooling-only models up to 250 L.

Hi! Recirculating Chillers control the temperature of external laboratory equipment. LC models heat and cool, from 0–99.9 °C to −80–80 °C on the LC-80; TLC models provide high-capacity cooling with 0 °C–RT or −20 °C–RT ranges and bath volumes up to 250 L.

Key features

  • LC: heating and cooling for external temperature control; LC-80 covers −80 to +80 °C
  • TLC: cooling-only, 10 to 250 L bath volume, two range options
  • PID control with ±0.1 °C accuracy and high/low alarms
  • Proportional cooling capacity control for energy saving

Why choose the Hi! Recirculating Chiller Series?

Every Hi! Science Essentials bath is supplied, installed and supported locally by Hi Pro Scientific, with calibration and preventive maintenance available.

LC Series – heating and cooling

Specification LC-06 LC-10 LC-18 LC-80
Temperature range 0 – 99.9 °C 0 – 99.9 °C 0 – 99.9 °C −80 – 80 °C
Temperature control accuracy ±0.1 °C ±0.1 °C ±0.1 °C ±0.1 °C
Controller PID microprocessor PID microprocessor PID microprocessor PID microprocessor
Alarm High / low temperature alarm High / low temperature alarm High / low temperature alarm High / low temperature alarm
Water circulation Built-in pump, inner and outer recirculation Built-in pump, inner and outer recirculation Built-in pump, inner and outer recirculation Built-in pump, inner and outer recirculation
Pump flow / pressure 6 L/min @ 0.25 bar 6 L/min @ 0.25 bar 6 L/min @ 0.25 bar 6 L/min @ 0.25 bar
Heating capacity 1,300 W 1,300 W 1,500 W 1,000 W
Cooling capacity (compressor) 1/5 HP 1/4 HP 1/2 HP 1 HP / 1 HP (cascade)
Overall dimensions (W×D×H) 330 × 530 × 670 mm (±50 mm) 370 × 585 × 680 mm 420 × 680 × 740 mm 1,100 × 850 × 900 mm
Bath volume 6 L 10 L Contact us 18 L
Interior material Stainless steel #304 Stainless steel #304 Stainless steel #304 Stainless steel #304
Exterior material Coated steel Coated steel Coated steel Coated steel
Cover SUS flat cover SUS flat cover SUS flat cover SUS flat cover
Safety device Overheat / overload protection Overheat / overload protection Overheat / overload protection Overheat / overload protection
Power Configured for local supply (specify at order) Configured for local supply (specify at order) Configured for local supply (specify at order) Configured for local supply (specify at order)

TLC Series – cooling only

Specification TLC-10A TLC-30A TLC-50A TLC-250
Temperature range 0 °C – RT or −20 °C – RT 0 °C – RT or −20 °C – RT 0 °C – RT or −20 °C – RT 0 °C – RT or −20 °C – RT
Temperature control accuracy ±0.1 °C ±0.1 °C ±0.1 °C ±0.1 °C
Controller PID microprocessor PID microprocessor PID microprocessor PID microprocessor
Alarm High / low temperature alarm High / low temperature alarm High / low temperature alarm High / low temperature alarm
Water circulation Built-in pump, inner and outer recirculation Built-in pump, inner and outer recirculation Built-in pump, inner and outer recirculation Built-in pump, inner and outer recirculation
Pump flow / pressure 20 L/min @ 1 bar 15 L/min @ 1 bar 40 L/min @ 3.5 bar 60 L/min @ 3.5 bar
Cooling capacity 1.2 kW 1 HP Contact us Contact us
Overall dimensions (W×D×H) 450 × 610 × 950 mm (±50 mm) 450 × 530 × 1,210 mm (±50 mm) 685 × 700 × 1,350 mm (±50 mm) 1,540 × 1,040 × 1,660 mm (±50 mm)
Bath volume 10 L 30 L 50 L 250 L
Interior material Stainless steel #304 Stainless steel #304 Stainless steel #304 Stainless steel #304
Exterior material Coated steel Coated steel Coated steel Coated steel
Cover SUS flat cover SUS flat cover SUS flat cover SUS flat cover
Power Configured for local supply (specify at order) Configured for local supply (specify at order) Configured for local supply (specify at order) Configured for local supply (specify at order)

Applications

  • Cooling rotary evaporators, reactors and condensers
  • Temperature control of analytical instruments
  • Heating and cooling external jacketed vessels (LC)

Related products

Hi! Water Bath Series · Hi! Circulating Water Bath Series · Hi! Stirrer Water Bath Series

FAQs

Q: What power supply does it need?
A: Units are configured for the local electrical supply; please specify your voltage when ordering.

Q: Do you offer calibration and service?
A: Yes. Hi Pro Scientific provides installation, temperature calibration and preventive maintenance across Singapore, Malaysia and Indonesia.

Installation, qualification and support

Hi Pro Scientific supplies, installs and commissions every unit, with IQ/OQ qualification and scheduled calibration and preventive maintenance available across Singapore, Malaysia and Indonesia.

Download the brochure (PDF)

Request a quote

Talk to our team about the Hi! Recirculating Chiller Series: configuration, lead time and pricing. Email info@hiproscientific.com or WhatsApp +65 8163 3185.

Model

LC-06, LC-10, LC-18, LC-80, TLC-10A, TLC-30A, TLC-50A, TLC-250

Reviews

There are no reviews yet.

Be the first to review “Hi! Recirculating Chiller Series”

Your email address will not be published. Required fields are marked *