Hi! Recirculating Chillers control the temperature of external laboratory equipment. LC models heat and cool, from 0–99.9 °C to −80–80 °C on the LC-80; TLC models provide high-capacity cooling with 0 °C–RT or −20 °C–RT ranges and bath volumes up to 250 L.
Key features
- LC: heating and cooling for external temperature control; LC-80 covers −80 to +80 °C
- TLC: cooling-only, 10 to 250 L bath volume, two range options
- PID control with ±0.1 °C accuracy and high/low alarms
- Proportional cooling capacity control for energy saving
Why choose the Hi! Recirculating Chiller Series?
Every Hi! Science Essentials bath is supplied, installed and supported locally by Hi Pro Scientific, with calibration and preventive maintenance available.
LC Series – heating and cooling
| Specification | LC-06 | LC-10 | LC-18 | LC-80 |
|---|---|---|---|---|
| Temperature range | 0 – 99.9 °C | 0 – 99.9 °C | 0 – 99.9 °C | −80 – 80 °C |
| Temperature control accuracy | ±0.1 °C | ±0.1 °C | ±0.1 °C | ±0.1 °C |
| Controller | PID microprocessor | PID microprocessor | PID microprocessor | PID microprocessor |
| Alarm | High / low temperature alarm | High / low temperature alarm | High / low temperature alarm | High / low temperature alarm |
| Water circulation | Built-in pump, inner and outer recirculation | Built-in pump, inner and outer recirculation | Built-in pump, inner and outer recirculation | Built-in pump, inner and outer recirculation |
| Pump flow / pressure | 6 L/min @ 0.25 bar | 6 L/min @ 0.25 bar | 6 L/min @ 0.25 bar | 6 L/min @ 0.25 bar |
| Heating capacity | 1,300 W | 1,300 W | 1,500 W | 1,000 W |
| Cooling capacity (compressor) | 1/5 HP | 1/4 HP | 1/2 HP | 1 HP / 1 HP (cascade) |
| Overall dimensions (W×D×H) | 330 × 530 × 670 mm (±50 mm) | 370 × 585 × 680 mm | 420 × 680 × 740 mm | 1,100 × 850 × 900 mm |
| Bath volume | 6 L | 10 L | Contact us | 18 L |
| Interior material | Stainless steel #304 | Stainless steel #304 | Stainless steel #304 | Stainless steel #304 |
| Exterior material | Coated steel | Coated steel | Coated steel | Coated steel |
| Cover | SUS flat cover | SUS flat cover | SUS flat cover | SUS flat cover |
| Safety device | Overheat / overload protection | Overheat / overload protection | Overheat / overload protection | Overheat / overload protection |
| Power | Configured for local supply (specify at order) | Configured for local supply (specify at order) | Configured for local supply (specify at order) | Configured for local supply (specify at order) |
TLC Series – cooling only
| Specification | TLC-10A | TLC-30A | TLC-50A | TLC-250 |
|---|---|---|---|---|
| Temperature range | 0 °C – RT or −20 °C – RT | 0 °C – RT or −20 °C – RT | 0 °C – RT or −20 °C – RT | 0 °C – RT or −20 °C – RT |
| Temperature control accuracy | ±0.1 °C | ±0.1 °C | ±0.1 °C | ±0.1 °C |
| Controller | PID microprocessor | PID microprocessor | PID microprocessor | PID microprocessor |
| Alarm | High / low temperature alarm | High / low temperature alarm | High / low temperature alarm | High / low temperature alarm |
| Water circulation | Built-in pump, inner and outer recirculation | Built-in pump, inner and outer recirculation | Built-in pump, inner and outer recirculation | Built-in pump, inner and outer recirculation |
| Pump flow / pressure | 20 L/min @ 1 bar | 15 L/min @ 1 bar | 40 L/min @ 3.5 bar | 60 L/min @ 3.5 bar |
| Cooling capacity | 1.2 kW | 1 HP | Contact us | Contact us |
| Overall dimensions (W×D×H) | 450 × 610 × 950 mm (±50 mm) | 450 × 530 × 1,210 mm (±50 mm) | 685 × 700 × 1,350 mm (±50 mm) | 1,540 × 1,040 × 1,660 mm (±50 mm) |
| Bath volume | 10 L | 30 L | 50 L | 250 L |
| Interior material | Stainless steel #304 | Stainless steel #304 | Stainless steel #304 | Stainless steel #304 |
| Exterior material | Coated steel | Coated steel | Coated steel | Coated steel |
| Cover | SUS flat cover | SUS flat cover | SUS flat cover | SUS flat cover |
| Power | Configured for local supply (specify at order) | Configured for local supply (specify at order) | Configured for local supply (specify at order) | Configured for local supply (specify at order) |
Applications
- Cooling rotary evaporators, reactors and condensers
- Temperature control of analytical instruments
- Heating and cooling external jacketed vessels (LC)
Related products
Hi! Water Bath Series · Hi! Circulating Water Bath Series · Hi! Stirrer Water Bath Series
FAQs
Q: What power supply does it need?
A: Units are configured for the local electrical supply; please specify your voltage when ordering.
Q: Do you offer calibration and service?
A: Yes. Hi Pro Scientific provides installation, temperature calibration and preventive maintenance across Singapore, Malaysia and Indonesia.
Installation, qualification and support
Hi Pro Scientific supplies, installs and commissions every unit, with IQ/OQ qualification and scheduled calibration and preventive maintenance available across Singapore, Malaysia and Indonesia.
Download the brochure (PDF)
Request a quote
Talk to our team about the Hi! Recirculating Chiller Series: configuration, lead time and pricing. Email info@hiproscientific.com or WhatsApp +65 8163 3185.






Reviews
There are no reviews yet.